Align scans (MS1)¶
Description¶
Raw data methods → Raw data filtering → Align scans (MS1)
This module aligns scans for small fluctuations correlating consecutive scans.
Parameters¶
Suffix¶
This string is added to filename as suffix.
Horizontal scans¶
Number of scans to be considered in the correlation (to the left and to the right of the scan being aligned).
Max Vertical Alignment¶
Maximum number of shifts to be compared. This depends on equipment, normally this should be 1.
Minimum height¶
Minimum intensity to be considered for align correlation.
If chromatogram height is below this level, it is not used in the correlation calculation.
Correlation in log¶
Transform intensities to log scale before comparing correlation.
Remove previous files¶
Remove processed files to save memory.
Last update: